Washington's crawl space code, stated once
Everything on this site about ground covers, vents and sealed crawl spaces comes from WAC 51-51-0408, Washington's amendment of section R408 of the national residential code (WSR 23-23-104, effective March 16, 2024). Other pages link here rather than restate it. Because Washington rewrote part of the national text, national articles about sealed crawl spaces can be wrong here.
The ground cover in a vented crawl space
A vented crawl space needs a ground cover: six-mil black polyethylene or an approved equal, laid over the ground, overlapped at the joints and run to the foundation wall. A concrete slab at least 2 inches thick is the exception.
The vents
The code asks for at least 1 square foot of net vent opening for every 300 square feet of crawl space floor, arranged for cross ventilation, with vent screen openings no larger than ¼ inch. Where the ground is covered with a Class I vapor retarder, the vent area may drop to 1 square foot per 1,500, as long as cross ventilation remains. Where ventilation falls below the 1-in-300 ratio, or operable louvers are used, the code calls for a radon vent starting under the cover.
The unvented crawl space (R408.3)
Washington's R408.3 says vent openings are not required where the crawl space has the following. The section lists the two items with no "and" or "or" between them:
- Exposed earth covered with a continuous Class I vapor retarder, joints overlapped 6 inches and sealed or taped, and edges extended at least 6 inches up the stem wall and attached and sealed there, and a radon system that meets Appendix AF of the code.
- Continuously operated mechanical exhaust ventilation at a rate of 1 cubic foot per minute for each 50 square feet of crawl space floor, discharged outside.
The text does not state outright whether both items must be met, so the building official, the City's or King County's, confirms how it applies to your house. An existing-structure plenum under M1601.5 is the one listed exception.
Two points are easy to get wrong:
- No dehumidifier in place of the exhaust. The national code text offers conditioned air or dehumidification as alternatives. Washington's list does not. A dehumidifier may be added to a sealed crawl space, but it never replaces the exhaust fan.