What Washington's code lists for an unvented crawl space
Washington amended the national model code's section R408.3. WAC 51-51-0408 says vent openings are not required where the crawl space has these two items, listed with no "and" or "or" between them:
- Exposed earth covered with a continuous Class I vapor retarder, joints overlapped 6 inches and sealed or taped, edges extended at least 6 inches up the stem wall and attached and sealed there, and a radon system that meets Appendix AF.
- Continuously operated mechanical exhaust at 1 cfm for each 50 square feet of crawl space floor, discharged outside.
The text does not say outright whether both items must be met, so the building official confirms how it applies to your house. Washington's list has no conditioned-air or dehumidifier option in place of the exhaust; that option is in the national text, not ours. A dehumidifier can be added to a sealed crawl space, but it never replaces the exhaust fan. Our permits guide covers which office reviews the work.
The exhaust rate is simple arithmetic. A 1,200 square foot crawl space needs 24 cfm of continuous exhaust, a small, quiet fan, running all the time.